C6925-0000
 

C6925-0000 | Fanless control cabinet Industrial PC

Variants Processor available
C6925-0000 Intel® Celeron® M ULV yes
C6925-0000
Fanless control cabinet PC 
Housing fanless industrial PC for space-saving control cabinet installation
mounting sheet at the rear wall
all connectors on the front
status LEDs
lithium battery accessible behind the front flap
1 slot for one 2½-inch hard disk or SSD behind the front flap
1 slot for one Compact Flash card behind the front flap
passive cooling without fan with a heat sink
5 cm (2") free space on top and bottom of the PC necessary for air circulation
protection class IP 20
operating temperature 0…55 °C
weight of the basic configuration 1.75 kg (3.9 lbs)
compact dimensions (W x H x D) 65 x 208 x 116 mm (2.6" x 8.2" x 4.6") without mounting plate
Features processor Intel® Celeron® M ULV 1.0 GHz
3½-inch motherboard for Intel® Celeron® M or Pentium® M
1 Mini PCI slot free for cards installed ex factory
256 MB DDR RAM, expandable ex factory to 2 GB
on-board graphic adapter, Intel® Extreme Graphic, DVI-I connector
on-board dual Ethernet adapter with 1 x 10/100BASE-T and 1 x 10/100/1000BASE-T connector
64 MB Compact Flash card, extended temperature range
1 serial port RS232 and 4 USB 2.0 ports
24 V DC power supply
operating system Microsoft Windows CE, English
Options C6925-0000
C9900-C532 processor Intel® Celeron® M 1.0 GHz, 0 kB L2 cache (Zero Second Level Cache)
instead of Intel® Celeron® M 1.0 GHz 512kB L2 cache, less price
C9900-R216 memory extension DDR RAM, additional price for each 256 MB
C9900-M653 mounting plate at the side wall, instead of plate at the rear wall
C9900-E159 Serial port COM2 RS232, optically linked, overload protection, D-sub 9-pin connector. An additional fieldbus interface card requires an additional connector bracket that is available at CP62xx with PCIe module slot, C65xx with PCIe module slot or at C6930, only.
C9900-E188 Serial port COM2 RS485, optically linked, overload protection, D-sub 9-pin connector. An additional fieldbus interface card requires an additional connector bracket that is available at CP62xx with PCIe module slot, C65xx with PCIe module slot or at C6930, only. Configuration as an end point without echo: echo off, auto send on, always send off, auto receive on, always receive off, termination on
C9900-E189 Serial port COM2 RS422, optically linked, overload protection, D-sub 9-pin connector. An additional fieldbus interface card requires an additional connector bracket that is available at CP62xx with PCIe module slot, C65xx with PCIe module slot or at C6930, only. Configuration as a full duplex end point: echo on, auto send off, always send on, auto receive off, always receive on, termination on
C9900-Z411 adapter plug DVI-I to VGA
C9900-Z413 adapter cable DVI-I to DVI and VGA 15 cm
C9900-R230 memory module NOVRAM for fail-safe storage of process data, 128 kB, Mini PCI plug-in card
C9900-R231 memory module NOVRAM for fail-safe storage of process data, 256 kB, Mini PCI plug-in card
C9900-R232 memory module NOVRAM for fail-safe storage of process data, 512 kB, Mini PCI plug-in card
C9900-H148 hard disk, 2½-inch, 40 GB, instead of 64 MB Compact Flash,
requires Windows Embedded Standard or Windows XP Professional
C9900-H703 solid-state disk SSD, 2½-inch, 32 GB, instead of 64 MB Compact Flash card, requires Windows Embedded Standard or Windows XP Professional
C9900-H161 hard disk, 2½-inch, 160 GB, instead of 64 MB Compact Flash,
requires Windows Embedded Standard or Windows XP Professional
C9900-H504 2 GB Compact Flash card, extended temperature range, instead of 64 MB Compact Flash
C9900-H505 4 GB Compact Flash card, extended temperature range, instead of 64 MB Compact Flash
C9900-H506 8 GB Compact Flash card, extended temperature range, instead of 64 MB Compact Flash
C9900-H507 16 GB Compact Flash card, extended temperature range, instead of 64 MB Compact Flash
C9900-D174 2 slots for Compact Flash cards, instead of 1 slot for a 2½-inch hard disk or SSD and 1 slot for Compact Flash
C9900-H515 2 GB Compact Flash card, extended temperature range
C9900-H516 4 GB Compact Flash card, extended temperature range
C9900-H517 8 GB Compact Flash card, extended temperature range
C9900-H518 16 GB Compact Flash card, extended temperature range
C9900-U209 uninterruptible power supply UPS, integrated into the 24 V power supply, without battery
C9900-U330 battery pack for PCs with 24 V power supply and integrated UPS C9900-P209 or C9900-U209, external, for DIN rail mounting, 3.4 Ah, operating temperature 0…50 °C
C9900-S326-0031 Microsoft Windows Embedded Standard image, German, requires at least
2 GB Compact Flash, instead of Windows CE, English
C9900-S326-0033 Microsoft Windows Embedded Standard image, English, requires at least
2 GB Compact Flash, instead of Windows CE, English
C9900-S309 Microsoft Windows Embedded Standard image adaption (all-in price per day)
C9900-S370 Microsoft Windows XP Professional, German, instead of Microsoft Windows CE, English
C9900-S371 Microsoft Windows XP Professional, English, instead of Microsoft Windows CE, English
C9900-S701 TwinCAT PLC run-time for Microsoft Windows CE
C9900-S702 TwinCAT NC PTP run-time for Microsoft Windows CE
C9900-S705 TwinCAT NC I run-time for Microsoft Windows CE